d1b9cf7ad1
Worker B found the exclusion detector's blind spot: opcode 0x08 (addi, traps on overflow) appears in 7 of 1,666 worklist rows (frame adjustments addi sp,sp,-28, loop counters) while 0 of 310 registered regions contains one — the same disjointness signal as finding 26's R-type class. addiu (0x09) is ubiquitous, so the 0x08 occurrences are the anomaly. Verified by the coordinator from raw words: 7 rows, incl. 3 of partition A's 5 call-shape rows (0x80011084, 0x800F3B10, 0x80010F30) and 0x800F3BB4 (previously recorded as a separate coordinator negative — now explained by this class). sf3_triage.trapping_arithmetic now counts opcode 0x08; worklist regenerated (1,563 rows, excluded_trapping_arith=54). Synthetic test added. P9-T5 route (a) widened: the immediate form is part of the class; the 7 ADDI rows are a ready-made minimal probe set for any cc1 candidate. Also confirmed this cycle: the no-frame global-ra ISR family (ra saved to a global, no stack frame — 0x801097A0 proved, 0x8010B420 pattern-transferred) is a second library-asm class identical in kind to the CRT entry.