Marek Vasut 3f9a91b6c0 drm/panel: simple: Fix Innolux G101ICE-L01 timings
The Innolux G101ICE-L01 datasheet [1] page 17 table
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
indicates that maximum vertical blanking time is 40 lines.
Currently the driver uses 29 lines.

Fix it, and since this panel is a DE panel, adjust the timings
to make them less hostile to controllers which cannot do 1 px
HSA/VSA, distribute the delays evenly between all three parts.

[1] https://www.data-modul.com/sites/default/files/products/G101ICE-L01-C2-specification-12042389.pdf

Fixes: 1e29b840af ("drm/panel: simple: Add Innolux G101ICE-L01 panel")
Signed-off-by: Marek Vasut <marex@denx.de>
Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20231008223256.279196-1-marex@denx.de