When initializing the PHY control register, the FIFO depth bits are
written without reading the previous register value, i.e. all other
bits are overwritten with zero. This disables automatic MDI-X
configuration, which is enabled by default. Fix initialization by doing
a read/modify/write operation.
Signed-off-by: Stefan Hauser <stefan@shauser.net>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>