Files
linux/drivers
Lars Ellenberg 9bd2eb2c98 drbd: also bump UUIDs if a diskless primary connects
If for some reason the primary lost its disk *and* the replication link
before it is able to communicate the disk loss, probably blocked IO,
then later is able to re-establish the connection, the peer needs to
bump its UUIDs just like it does when peer only loses the disk
and is able to communicate this in time.

Otherwise, a later re-attach of the disk on the primary may start a
resync in the "wrong" direction.

Signed-off-by: Philipp Reisner <philipp.reisner@linbit.com>
Signed-off-by: Lars Ellenberg <lars.ellenberg@linbit.com>
Signed-off-by: Jens Axboe <axboe@fb.com>
2015-11-25 09:22:01 -07:00
..
2015-11-20 01:22:33 +01:00
2015-10-29 09:02:16 +09:00
2015-11-08 16:24:43 -05:00
2015-11-10 16:32:11 -08:00
2015-11-20 16:19:54 -08:00