mirror of
https://github.com/RetroPortingToolKit/psxrecomp
synced 2026-10-26 10:19:47 -04:00
e88e9a0233
Before: only sector 0 read succeeded; sector ≥1 reads aborted at 2 bytes
because mc_flag was loaded from mc_slots[].flag on every 0x81 select but
never saved back. The clear in MC_CMD lived only in the working static, so
every reselect re-loaded the stale 0x08 ("new card / changed battery") init
value, and the BIOS bailed every multi-sector op as "card was just inserted,
re-init."
After: BIOS shell memcard menu reads the full 15-sector directory area for
both slots. Real save filenames decode (e.g. "BISLPS-01234SAVE00") and per
card icons render in the bottom panes — the Phase 4 success criterion.
Also bundled this session:
- debug_server: B9D0..B9F0 added to always-on wtrace ranges; fn_dump_parse
default window scoped to 1M most-recent entries (filter scans against the
full 128M ring used to freeze the debug server thread for many seconds).
- ISSUES.md + diagnostic tools/*.py written during the audit.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
23 lines
830 B
Python
23 lines
830 B
Python
"""fn_exit_dump for a function. Args: addr_lo addr_hi"""
|
|
import socket, json, sys
|
|
addr_lo = sys.argv[1]
|
|
addr_hi = sys.argv[2]
|
|
s = socket.create_connection(('127.0.0.1', 4370), timeout=120)
|
|
s.sendall((json.dumps({
|
|
'id': 1, 'cmd': 'fn_exit_dump',
|
|
'addr_lo': addr_lo, 'addr_hi': addr_hi,
|
|
'seq_lo': '0', 'seq_hi': '999999999999', 'count': 50,
|
|
}) + '\n').encode())
|
|
buf = b''
|
|
while True:
|
|
c = s.recv(65536)
|
|
if not c: break
|
|
buf += c
|
|
if buf.strip().endswith(b'}'):
|
|
try: json.loads(buf.decode()); break
|
|
except: continue
|
|
r = json.loads(buf.decode())
|
|
print(f"total={r.get('total')} oldest={r.get('oldest')} returned={len(r.get('entries', []))}")
|
|
for e in r.get('entries', [])[:30]:
|
|
print(f" seq={e['seq']} entry={e['entry_seq']} func={e['func']} v0={e['v0']} v1={e['v1']} frame={e['frame']}")
|